Transient & surge analysis

Transient and surge analysis for aviation fuel hydrant systems

Surge (water hammer) is the pressure wave that follows a quick change: a pit valve or an ESD valve closing, a pump tripping. flownet runs these events on your network, finds the highest and lowest pressure along every pipe, flags cavities, and proves what would fix a failing case.

Surge cases recommended from your model

Ask for recommended cases and flownet suggests them: the farthest pit valve closing, the ESD set closing, and the pump cases when the model has pumps. Each starts from a steady case and can run from others too.

  • Time step chosen from the shortest pipe, so you do not have to.
  • Monitor points you pick for graphs of pressure against time.
  • Inputs table listing every case, event and figure on one page before you run.
  • Runs in the background: leave the page and come back.
Surge at two hydrant pits after a pit valve closes over 2 seconds: pressure in bar g against time in seconds, with the allowable surge pressure and the vapour line04812162024048121620TIME, sPRESSURE, bar gAllowable surge pressureVapour lineCLOSUREPeak 13.3 bar g at 4.0 sHP-105 (farthest pit)HP-101
Pressure against time at two pits, with the allowable and the vapour line · illustration
Events

The events that matter on an apron

Close a valve

A pit valve, an ESD valve or a whole named set, at a time and over a time you give, straight or in stages.

Trip or start a pump

A pump stops or starts and the wave travels both ways round the loop.

Shut an offtake

A hydrant point stops drawing as an aircraft finishes.

Check valve slam

A non-return valve closes on reverse flow.

Pass or check, pipe by pipe

  • Across the cases: one row per case with the highest pressure, where and when, and the lowest.
  • Pipe envelope: maximum and minimum on each pipe against the surge allowance of ASME B31.4 and what the wall contains.
  • Column separation: pressure reaching the vapour line is flagged, plotted and shown as cavities on the long section.
  • What the run assumed: fluid, wave speeds, valve curves, and the part of the closure that governed.
  • Replay: the run plays on the drawing, the long section and the graphs together.
What would fix it

A failing case comes with options, already run

The preferred order is the engineer's: change the closure or the pipe before adding equipment. flownet sizes each option and re-runs the case to prove it.

1 · Slower closure

The closure time that keeps every pipe within its allowable.

2 · Larger bore

The pipes to upsize and by how much.

3 · Surge vessel

Sized, placed and re-run.

4 · Relief valve

Sized to API 520 and re-run.

Run a surge case on your network

We will run a pit valve closure and an ESD closure on your layout in a live demo.